inquiry
оставить сообщение
Если вас заинтересовала наша продукция и вы хотите узнать более подробную информацию, оставьте сообщение здесь, и мы ответим вам как можно скорее.
ПРЕДСТАВЛЯТЬ НА РАССМОТРЕНИЕ
Компания Bengbu Longkai Welding Protection Technology Co., Ltd.
ДОМ

бумажная респираторная маска

бумажная респираторная маска

  • Demolition Work: Choosing the Right PAPR
    Demolition Work: Choosing the Right PAPR
    Jan 20, 2026
      Demolition work involves complex and variable environments. From breaking down walls of old buildings to dismantling industrial facilities, pollutants such as dust, harmful gases, and volatile organic compounds (VOCs) are pervasive, placing extremely high demands on respiratory protection for workers. battery powered respirator have become core protective equipment in demolition work due to their advantages of positive pressure protection and low breathing load. However, not all PAPRs are suitable for all scenarios; selecting the right type is essential to build a solid line of defense for respiratory safety. Compared with traditional negative-pressure respirators, PAPRs actively deliver air through an electric fan, which not only reduces breathing fatigue during high-intensity operations but also prevents pollutant leakage through the positive pressure environment inside the mask, significantly improving protection reliability.   For general dust-generating demolition operations, particulate-filtering PAPRs are preferred. Such operations commonly involve the demolition of concrete, masonry, wood, and other components, with respirable dust—especially PM2.5 fine particles—as the primary pollutant. Long-term inhalation can easily induce pneumoconiosis. When selecting a model, high-efficiency particulate filters should be used, and the mask can be chosen based on operational flexibility needs. For open-air scenarios such as ordinary wall breaking and floor demolition, air-fed hood-type PAPRs are more suitable. They do not require a facial fit test, offer strong adaptability, and can also provide head impact protection. For narrow workspaces with extremely high dust concentrations, it is recommended to use tight-fitting full-face PAPRs, which have a minimum air flow rate of no less than 95L/min, forming a tight seal on the face to prevent dust from seeping through gaps.   For demolition operations involving harmful gases, combined-filtering PAPRs are required. During the demolition of old buildings, volatile organic compounds such as formaldehyde and benzene are emitted from paints and coatings, while the dismantling of industrial facilities may leave toxic gases such as ammonia and chlorine. In such cases, a single particulate-filtering PAPR cannot meet protection needs. Dual-filter elements (particulate + gas/vapor) should be used, with precise selection based on pollutant types: activated carbon filter cartridges for organic vapors, and chemical adsorption filter elements for acid gases. For these scenarios, positive-pressure tight-fitting PAPRs are preferred. Combined with forced air supply, they not only effectively filter harmful gases but also reduce pollutant residue inside the mask through continuous air supply, while avoiding poisoning risks caused by mask leakage.   Special scenarios require targeted selection of dedicated loose fitting powered air purifying respirators. Demolishing asbestos-containing components is a high-risk operation—once inhaled, asbestos fibers cause irreversible lung damage. PAPRs complying with asbestos protection standards should be used, paired with high-efficiency HEPA filters. Additionally, hood-type designs must be adopted to avoid fiber leakage due to improper wearing of tight-fitting masks. Meanwhile, the hood should be used with chemical protective clothing to form full-body protection. For demolition in confined spaces such as basements and pipe shafts, oxygen levels must first be tested. If the oxygen concentration is not less than 19% (non-IDLH environment), portable positive-pressure PAPRs can be used with forced ventilation systems. If there is a risk of oxygen deficiency, supplied-air respirators must be used instead of relying on PAPRs.   PAPR selection must balance compliance with standards and operational practicality.  Adjustments should also be made based on labor intensity: most demolition work is moderate to high intensity, so Powered Air Purifying Respirator TH3 are more effective in reducing breathing load, preventing workers from removing protective equipment due to fatigue. Battery life must match operation duration—for long-term outdoor operations, replaceable battery models are recommended to ensure uninterrupted protection. Furthermore, filter elements must be replaced strictly on schedule: gas filter cartridges should be replaced within 6 months of opening, or immediately if odors occur or resistance increases, to avoid protection failure.   Finally, it should be noted that PAPRs are not universal protective equipment, and their use must be based on a comprehensive risk assessment. Before demolition work, on-site testing should be conducted to identify pollutant types, concentrations, and environmental characteristics, followed by selecting the appropriate PAPR type for the scenario.  Only by selecting and using PAPRs correctly can we build a reliable barrier for respiratory health in complex demolition work, balancing operational efficiency and safety protection.If you want know more, please click www.newairsafety.com.
    ЧИТАТЬ ДАЛЕЕ
  • PAPR Air Inlet Modes: Practical Differences & Selection Logic
    PAPR Air Inlet Modes: Practical Differences & Selection Logic
    Jan 16, 2026
      In air purification respirator application scenarios, most users focus more on filtration efficiency and protection level, but often overlook the potential impact of air inlet modes on actual operations. this article focuses on the differences of front, side and back air inlet modes in wearing adaptability, scenario compatibility, energy consumption control and special population adaptation from the perspective of on-site operational needs. The choice of air inlet mode is not only related to protection effect but also directly affects operational continuity, equipment loss rate and employees' acceptance of the equipment. Its importance becomes more prominent especially in scenarios with multiple working condition switches and long-term operations.   The core competitiveness of front air inlet PAPR lies in lightweight adaptation and emergency scenario compatibility, rather than simple air flow efficiency. This design concentrates the core air inlet and filter components in front of the head, with the overall equipment weight more concentrated and the center of gravity forward, adapting to most standard head shapes without additional adjustment of back or waist load, being more friendly to workers who are thin or have old back injuries. In emergency rescue, temporary inspection and other scenarios, the front air inlet PAPR has significant advantages in quick wearing; without cumbersome hose connection, it can be worn immediately after unpacking, gaining time for emergency disposal. However, potential shortcomings cannot be ignored: the forward center of gravity may cause neck soreness after long-term wearing, especially when used with safety helmets, the head load pressure is concentrated, making it unsuitable for continuous operations of more than 8 hours; at the same time, the front air inlet is easily blown back by breathing air flow, leading to moisture condensation on the surface of the filter unit, which is prone to mold growth in high-humidity environments, affecting filter service life and respiratory health.   The core advantage of side air inlet PAPR is multi-equipment coordination adaptability and air flow comfort, which is the key to its being the first choice for comprehensive working conditions. In industrial scenarios, workers often need to match safety helmets, goggles, communication equipment and other equipment. The arrangement of the side air inlet unit can avoid the equipment space in front of and on the top of the head, prevent mutual interference, and not affect the wearing stability of the safety helmet. Compared with the direct air flow of the front air inlet, the side air inlet can achieve "face-surrounding air supply" through a flow guide structure, with softer air flow speed, avoiding dryness caused by direct air flow to the nasal cavity and eyes, and greatly improving tolerance for long-term operations. Its limitations are mainly reflected in bilateral adaptability: single-side air inlet may lead to uneven head force, while double-side air inlet will increase equipment volume, which may collide with shoulder protective equipment and operating tools; in addition, the flow guide channel of the side air inlet unit is narrow; if the filtration precision of the filter unit is insufficient, impurities are likely to accumulate at the flow guide port, affecting air flow smoothness.   The core value of back air inlet papr air purifier lies in extreme working condition adaptation and equipment loss control, especially suitable for high-frequency and high-intensity operation scenarios. Integrating core components such as air inlet, power and battery into the back, only a lightweight hood and air supply hose are retained on the head, which not only completely frees up the head operation space but also avoids collision and wear of core components during operation, significantly reducing equipment maintenance and replacement costs. The weight of the back component is evenly distributed; matched with adjustable waist belt and shoulder straps, it can disperse the load to the whole body. Compared with front and side air inlets, it is more suitable for long-term and high-intensity operations. Moreover, the long back air flow path can be equipped with a simple heat dissipation structure to alleviate equipment overheating in high-temperature environments. However, this mode has certain requirements for the working environment: the back component is relatively large, unsuitable for narrow spaces, climbing operations and other scenarios; as the core connection part, if the hose material has insufficient toughness, it is prone to bending and aging during large limb movements, and dust is easy to accumulate on the inner wall of the hose, making daily cleaning more difficult than front and side air inlet equipment.   The core logic of selection is the adaptive unity of "human-machine-environment", rather than the optimal single performance. If the operation is mainly temporary inspection and emergency disposal with high personnel mobility, front air inlet PAPR should be preferred to balance wearing efficiency and lightweight needs; for regular industrial operations requiring multiple protective equipment and long operation time, side air inlet is the choice balancing comfort and coordination; for high-frequency, high-intensity operations with strict requirements on equipment loss control, back air inlet is more cost-effective. In addition, special factors should be considered: front air inlet should be avoided in high-humidity environments to prevent moisture condensation; back air inlet should be excluded in narrow space operations, and lightweight front or side air inlet should be preferred; for scenarios with high communication needs, side air inlet is easier to coordinate with communication equipment.   The iterative design of papr respirator air inlet modes is essentially the in-depth adaptation to operational scenario needs. From the initial front air inlet to meet basic protection, to the side air inlet balancing comfort and coordination, and then to the back air inlet adapting to extreme working conditions, each mode has its irreplaceable value. For enterprises, selection should not only focus on equipment parameters but also combine feedback from front-line workers and detailed differences of operation scenarios, so that PAPR can become an assistant to improve operational efficiency rather than a burden while ensuring safety. In the future, with the popularization of modular design, switchable air inlet modes may become mainstream, further breaking the scenario limitations of a single air inlet mode.If you want know more, please click www.newairsafety.com.
    ЧИТАТЬ ДАЛЕЕ
  • Ключевые компоненты противогазовых баллонов: «целевые составы», соответствующие «типам защищаемого газа»
    Ключевые компоненты противогазовых баллонов: «целевые составы», соответствующие «типам защищаемого газа»
    Aug 26, 2025
    Основные компоненты противогазовых баллонов значительно различаются в зависимости от цели защиты (серии A/B/E/K). По сути, «определённые компоненты используются для учёта химических свойств определённых газов» — точность, которая крайне важна при использовании этих баллонов с Электроприводные воздухоочистительные респираторы, которые не могут компенсировать несоответствие или неэффективность фильтрующих материалов. Ниже приведено объяснение, соответствующее классификации газов, упомянутой ранее, с акцентом на важность PAPR:​1. Для серии A (органические газы/пары, например, бензол, бензин): активированный уголь в качестве ядра​Основной компонент: активированный уголь с высокой удельной площадью поверхности (в основном, уголь из скорлупы кокосовых орехов или уголь на основе угля, с пористостью более 90%. Площадь поверхности 1 грамма активированного угля эквивалентна площади футбольного поля).Принцип работы: использует «физическую адсорбцию» активированного угля — молекулы органических газов адсорбируются в микропорах активированного угля за счёт сил Ван-дер-Ваальса и не могут попасть в зону дыхания вместе с потоком воздуха. Это делает его идеальным для использования в респираторы с очисткой воздуха с помощью бумажных фильтров применяются при работах по покраске или работе с растворителями, где постоянное воздействие органических паров требует надежной и длительной адсорбции.Улучшенная оптимизация: для органических газов с низкой температурой кипения в серии A3 (например, метана, пропана, которые чрезвычайно летучи) используется «пропитанный активированный уголь» (с добавлением небольших количеств веществ, таких как силикон), что повышает адсорбционную способность для низкомолекулярных органических газов, что критически важно для респиратор с очисткой воздуха под положительным давлением используется на нефтеперерабатывающих заводах или заводах по переработке природного газа. 2. Для серии B (неорганические газы/пары, например, хлор, диоксид серы): химические адсорбенты как основной компонент​Основной компонент: пропитанный активированный уголь + оксиды металлов (например, сульфат меди, перманганат калия, гидроксид кальция).Принцип работы: Большинство неорганических газов обладают сильными окисляющими или раздражающими свойствами и должны быть преобразованы в безвредные вещества посредством «химических реакций». Например:Хлор (Cl₂) реагирует с гидроксидом кальция с образованием хлорида кальция (безвредного твердого вещества);Диоксид серы (SO₂) окисляется до сульфата (фиксируется в фильтрующем материале после растворения в воде) путем реакции с перманганатом калия.Такая химическая стабильность является обязательным требованием для электроприводных воздухоочистительных респираторов, используемых на химических производственных предприятиях, где внезапные скачки концентрации неорганических газов требуют быстрой и эффективной нейтрализации.​3. Для серии E (кислые газы/пары, например, соляная кислота, фтористый водород): щелочные нейтрализаторы​Основной компонент: гидроксид калия (KOH), гидроксид натрия (NaOH) или карбонат натрия (нанесенный на активированный уголь или инертные носители).Принцип работы: использует реакцию кислотно-щелочной нейтрализации для преобразования кислых газов в соли (безвредные и нелетучие). Например:Соляная кислота (HCl) реагирует с гидроксидом калия с образованием хлорида калия (KCl) и воды;Фтористый водород (HF) реагирует с гидроксидом натрия, образуя фторид натрия (NaF, твердое вещество), что предотвращает его разъедание дыхательных путей.Эта устойчивая к коррозии формула имеет решающее значение для электроприводных воздухоочистительных респираторов, используемых в травильных цехах или при производстве полупроводников, где пары кислот представляют опасность как для здоровья, так и для оборудования.​4. Для серии K (газы/пары аммиака и амина, например, аммиак, метиламин): кислотные адсорбенты​Основной компонент: активированный уголь, пропитанный фосфорной кислотой (H₃PO₄), или сульфат кальция.Принцип работы: аммиак и амины являются щелочными газами и связываются посредством кислотно-щелочной нейтрализации. Например:Аммиак (NH₃) реагирует с фосфорной кислотой с образованием фосфата аммония ((NH₄)₃PO₄, твердое вещество);Метиламин (CH₃NH₂) реагирует с сульфатом кальция с образованием устойчивых солей, которые больше не улетучиваются.Такая целевая нейтрализация имеет решающее значение для электроприводных воздухоочистительных респираторов, используемых на заводах по производству удобрений или в холодильных складах, где утечки аммиака представляют собой распространённую опасность.​III. «Логика соответствия» между конструкцией и компонентами: почему нельзя использовать разные типы противогазов?​Из вышеизложенного следует, что «слоистая структура» и «выбор компонентов» противогазовых баллонов полностью разработаны с учётом «цели защиты» — принципа, который становится ещё более важным в сочетании с электроприводными воздухоочистительными респираторами, поскольку эти устройства усиливают как эффективность правильных баллонов, так и риски использования неправильных:​Если для защиты от кислотных газов серии E с помощью электроприводных воздухоочистительных респираторов используется противогазовый контейнер серии A (с активированным углем), кислотные газы будут напрямую проникать в активированный уголь (реакция нейтрализации не происходит), а непрерывный поток воздуха PAPR будет доставлять эти неотфильтрованные газы прямо к пользователю;Если фильтр противогаза серии K (кислотный адсорбент) подвергается воздействию хлора серии B (сильно окисляющего) в электроприводных воздухоочистительных респираторах, могут возникнуть неблагоприятные реакции и даже образоваться токсичные вещества, которые PAPR затем будет распространять в зоне дыхания.Это также перекликается с «золотым правилом выбора», упомянутым ранее: противогазовые баллоны соответствующей серии должны выбираться в соответствии с типом газа в рабочей среде, чтобы гарантировать, что конструкция и компоненты действительно выполняют свою функцию, особенно при использовании с электроприводными воздухоочистительными респираторами.​Заключение​Корпус противогаза — это не просто «контейнер из одного материала», а сложная комбинация «слоистой структуры и целевых компонентов», разработанная для гармоничного взаимодействия с электроприводными воздухоочистительными респираторами. Внешняя оболочка обеспечивает герметичность воздушного потока PAPR, слой предварительной обработки отфильтровывает примеси для поддержания эффективности PAPR, а адсорбционно-нейтрализующий слой сердцевины точно улавливает определённые газы, поддерживая чистоту подаваемого PAPR воздуха. В конечном счёте, он обеспечивает защитный эффект, «предотвращая проникновение вредных газов и обеспечивая выход чистого воздуха». Понимание этих деталей не только помогает нам более научно подбирать фильтры для противогазов для стандартных масок, но и имеет ещё более важное значение для пользователей электроприводных воздухоочистительных респираторов, которые полагаются на синергию фильтра и PAPR для обеспечения постоянной и надёжной защиты. Это также позволяет нам более чётко определять, когда следует заменять фильтры во время использования (например, защитный эффект резко снизится после насыщения адсорбционного слоя), добавляя «линию защиты» для обеспечения безопасности органов дыхания, особенно для тех, кто использует электроприводные воздухоочистительные респираторы в условиях повышенного риска. Чтобы узнать больше, нажмите здесь. www.newairsafety.com.
    ЧИТАТЬ ДАЛЕЕ

оставить сообщение

оставить сообщение
Если вас заинтересовала наша продукция и вы хотите узнать более подробную информацию, оставьте сообщение здесь, и мы ответим вам как можно скорее.
ПРЕДСТАВЛЯТЬ НА РАССМОТРЕНИЕ
СВЯЗАТЬСЯ С НАМИ: sales@txhyfh.com

ДОМ

ПРОДУКЦИЯ

Ватсап

Связаться с нами